RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2508028137 - Archived data from Fri, 05. February 2021 11:10:08 CET


This is all the information about APD 2508028137. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2508028137
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D09
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 380.6 V
Dark current: 5.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 169
Position in Box: 27
EP1 batch: 23
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jul 2019
Sent for analysis after irradiation: 19. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 16. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 380.4902148 V     T = -25 °C: 345.5894373 V
Voltage for Gain 150: T = +20 °C: 388.3199036 V     T = -25 °C: 352.9137531 V
Voltage for Gain 200: T = +20 °C: 392.7059601 V     T = -25 °C: 356.9761887 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.591752141 V-1     T = -25 °C: 4.765505559 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.055633656 V-1     T = -25 °C: 9.055706173 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.130672 V-1     T = -25 °C: 16.5315478 V-1
Break-through voltage: T = +20 °C: 408.7000902 V     T = -25 °C: 372.2417536 V
   
Notes:


Version history

Time Author Change comment
26. Apr 2021 14:28:33 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:10:08 CET jreher Updated box and position via API.
11. Aug 2020 17:31:15 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:58:49 CET jreher Updated APD location via API.
25. Nov 2019 17:24:14 CET jreher Updated box and position via API.
30. Jul 2019 15:16:05 CEST spankonin Updated APD batch assignment via API.
19. Jul 2019 09:54:25 CEST markus.moritz
05. Jul 2019 13:58:37 CEST jreher Updated APD location via API.
24. Jun 2019 13:56:24 CEST jgrochowski Updated APD batch assignment via API.
03. Jan 2019 00:12:13 CET Tobias Corrected dark current unit.
12. Jan 2018 13:12:02 CET Tobias Imported from Hamamatsu datasheet.