Subdetector specification:  
Serial: 2508028102
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2508028102/2309024868
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: blue
   
Manufacturer information:  
Wafer position: C06
Break-through voltage: 410 V
Voltage for Gain 100 (T=+25°C): 381.4 V
Dark current: 6.5 nA
   
Screening Logistics:  
Available: No
Storage Box: 169
Position in Box: 27
EP1 batch: 22
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jul 2019
Sent for analysis after irradiation: 19. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 16. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.099052 V     T = -25 °C: 346.1070074 V
Voltage for Gain 150: T = +20 °C: 388.9733122 V     T = -25 °C: 353.4730733 V
Voltage for Gain 200: T = +20 °C: 393.3407929 V     T = -25 °C: 357.5938104 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.510073582 V-1     T = -25 °C: 4.939236297 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.296927231 V-1     T = -25 °C: 9.434003177 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.80699665 V-1     T = -25 °C: 15.16648543 V-1
Break-through voltage: T = +20 °C: 409.181318 V     T = -25 °C: 372.9425802 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:10:06 CET jreher Updated box and position via API.
11. Aug 2020 17:31:11 CEST jreher Updated APD characteristics via API.
25. Jun 2020 11:21:58 CEST jreher Assigned to capsule by script
19. Feb 2020 11:53:40 CET jreher Updated box and position via API.
27. Nov 2019 19:58:48 CET jreher Updated APD location via API.
25. Nov 2019 17:24:12 CET jreher Updated box and position via API.
30. Jul 2019 15:16:04 CEST spankonin Updated APD batch assignment via API.
19. Jul 2019 09:47:27 CEST markus.moritz
05. Jul 2019 13:58:36 CEST jreher Updated APD location via API.
24. Jun 2019 13:38:18 CEST jgrochowski Updated APD batch assignment via API.
03. Jan 2019 00:12:13 CET Tobias Corrected dark current unit.
12. Jan 2018 13:12:02 CET Tobias Imported from Hamamatsu datasheet.