Subdetector specification:  
Serial: 2508028098
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E03
Break-through voltage: 415 V
Voltage for Gain 100 (T=+25°C): 386.4 V
Dark current: 6.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 169
Position in Box: 17
EP1 batch: 22
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jul 2019
Sent for analysis after irradiation: 19. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 16. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 385.7108384 V     T = -25 °C: 350.5151277 V
Voltage for Gain 150: T = +20 °C: 393.6085477 V     T = -25 °C: 357.9439685 V
Voltage for Gain 200: T = +20 °C: 398.0003775 V     T = -25 °C: 362.0703465 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.469446858 V-1     T = -25 °C: 4.714839255 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.599098242 V-1     T = -25 °C: 9.927908099 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.34437476 V-1     T = -25 °C: 16.27249845 V-1
Break-through voltage: T = +20 °C: 413.946684 V     T = -25 °C: 377.4917366 V
   
Notes:


Version history

Time Author Change comment
16. Nov 2021 10:35:01 CET oafedulidis Assigned to capsule by script
16. Jun 2021 16:03:29 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:59:47 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:52:27 CEST oafedulidis Updated box and position via API.
26. Apr 2021 14:28:32 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:10:05 CET jreher Updated box and position via API.
11. Aug 2020 17:31:11 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:58:48 CET jreher Updated APD location via API.
25. Nov 2019 17:24:12 CET jreher Updated box and position via API.
30. Jul 2019 15:16:03 CEST spankonin Updated APD batch assignment via API.
19. Jul 2019 09:46:03 CEST markus.moritz
05. Jul 2019 13:58:36 CEST jreher Updated APD location via API.
24. Jun 2019 13:38:18 CEST jgrochowski Updated APD batch assignment via API.
03. Jan 2019 00:12:13 CET Tobias Corrected dark current unit.
12. Jan 2018 13:12:02 CET Tobias Imported from Hamamatsu datasheet.