RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2508028088 - Archived data from Fri, 05. February 2021 11:10:04 CET


This is all the information about APD 2508028088. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2508028088
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: A07
Break-through voltage: 414 V
Voltage for Gain 100 (T=+25°C): 385.1 V
Dark current: 15.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 169
Position in Box: 15
EP1 batch: 22
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jul 2019
Sent for analysis after irradiation: 19. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 16. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 385.0516071 V     T = -25 °C: 349.6704779 V
Voltage for Gain 150: T = +20 °C: 392.9331843 V     T = -25 °C: 357.1111267 V
Voltage for Gain 200: T = +20 °C: 397.2822841 V     T = -25 °C: 361.2850425 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.514567969 V-1     T = -25 °C: 4.711174766 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.486352972 V-1     T = -25 °C: 9.603094812 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.89023351 V-1     T = -25 °C: 15.49446943 V-1
Break-through voltage: T = +20 °C: 403.9329332 V     T = -25 °C: 376.8102026 V
   
Notes:


Version history

Time Author Change comment
14. Apr 2021 18:51:59 CEST oafedulidis Assigned to capsule by script
16. Feb 2021 12:28:38 CET jreher Updated box and position via API.
05. Feb 2021 11:10:04 CET jreher Updated box and position via API.
11. Aug 2020 17:31:09 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:58:47 CET jreher Updated APD location via API.
25. Nov 2019 17:24:12 CET jreher Updated box and position via API.
30. Jul 2019 15:16:03 CEST spankonin Updated APD batch assignment via API.
19. Jul 2019 09:32:23 CEST markus.moritz
05. Jul 2019 13:58:35 CEST jreher Updated APD location via API.
24. Jun 2019 13:38:17 CEST jgrochowski Updated APD batch assignment via API.
03. Jan 2019 00:12:12 CET Tobias Corrected dark current unit.
12. Jan 2018 13:12:02 CET Tobias Imported from Hamamatsu datasheet.