Show Hamamatsu Avalanche Photo Diode 2507028065 - Archived data from Mon, 17. May 2021 09:17:54 CEST


This is all the information about APD 2507028065. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2507028065
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G13
Break-through voltage: 419 V
Voltage for Gain 100 (T=+25°C): 392.3 V
Dark current: 5.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 169
Position in Box: 10
EP1 batch: 22
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jul 2019
Sent for analysis after irradiation: 19. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 16. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 392.0737273 V     T = -25 °C: 356.0193091 V
Voltage for Gain 150: T = +20 °C: 399.9178405 V     T = -25 °C: 363.593943 V
Voltage for Gain 200: T = +20 °C: 404.2492988 V     T = -25 °C: 367.8376695 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.611850384 V-1     T = -25 °C: 4.835149601 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.320271101 V-1     T = -25 °C: 8.829030498 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.66148802 V-1     T = -25 °C: 15.82656993 V-1
Break-through voltage: T = +20 °C: 419.8092122 V     T = -25 °C: 383.5403178 V
   
Notes:


Version history

Time Author Change comment
27. Sep 2021 16:13:16 CEST oafedulidis Assigned to capsule by script
17. May 2021 09:17:54 CEST oafedulidis Updated box and position via API.
26. Apr 2021 14:28:31 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:10:04 CET jreher Updated box and position via API.
11. Aug 2020 17:31:09 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:58:47 CET jreher Updated APD location via API.
25. Nov 2019 17:24:11 CET jreher Updated box and position via API.
30. Jul 2019 15:15:51 CEST spankonin Updated APD batch assignment via API.
19. Jul 2019 09:31:22 CEST markus.moritz
05. Jul 2019 13:58:35 CEST jreher Updated APD location via API.
24. Jun 2019 13:38:17 CEST jgrochowski Updated APD batch assignment via API.
03. Jan 2019 00:12:12 CET Tobias Corrected dark current unit.
12. Jan 2018 13:12:02 CET Tobias Imported from Hamamatsu datasheet.