RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2507028052 - Archived data from Wed, 16. June 2021 15:52:25 CEST


This is all the information about APD 2507028052. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2507028052
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E11
Break-through voltage: 415 V
Voltage for Gain 100 (T=+25°C): 386.8 V
Dark current: 6.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 168
Position in Box: 48
EP1 batch: 21
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jul 2019
Sent for analysis after irradiation: 19. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 16. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 386.3217825 V     T = -25 °C: 350.5065754 V
Voltage for Gain 150: T = +20 °C: 394.2221509 V     T = -25 °C: 357.9494043 V
Voltage for Gain 200: T = +20 °C: 398.5976234 V     T = -25 °C: 362.0928921 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.484302043 V-1     T = -25 °C: 4.721285243 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.941987491 V-1     T = -25 °C: 9.705760569 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.91055556 V-1     T = -25 °C: 15.52634339 V-1
Break-through voltage: T = +20 °C: 414.1139057 V     T = -25 °C: 377.1335283 V
   
Notes:


Version history

Time Author Change comment
16. Nov 2021 10:33:26 CET oafedulidis Assigned to capsule by script
16. Jun 2021 16:03:27 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:59:46 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:52:25 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:10:00 CET jreher Updated box and position via API.
11. Aug 2020 17:31:06 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:58:39 CET jreher Updated APD location via API.
25. Nov 2019 17:24:09 CET jreher Updated box and position via API.
30. Jul 2019 15:15:50 CEST spankonin Updated APD batch assignment via API.
19. Jul 2019 09:24:18 CEST markus.moritz
05. Jul 2019 13:58:30 CEST jreher Updated APD location via API.
24. Jun 2019 13:27:21 CEST jgrochowski Updated APD batch assignment via API.
03. Jan 2019 00:12:12 CET Tobias Corrected dark current unit.
12. Jan 2018 13:12:02 CET Tobias Imported from Hamamatsu datasheet.