Show Hamamatsu Avalanche Photo Diode 2507028049 - Archived data from Tue, 11. August 2020 17:31:06 CEST
This is all the information about APD 2507028049. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2507028049 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | B09 |
Break-through voltage: | 417 V |
Voltage for Gain 100 (T=+25°C): | 388.7 V |
Dark current: | 6.4 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 168 |
Position in Box: | 45 |
EP1 batch: | 21 |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | 16. Jul 2019 |
Sent for analysis after irradiation: | 19. Jul 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 16. Jul 2019 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 17. Jul 2019 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 389.5785782 V T = -25 °C: 354.0904935 V |
Voltage for Gain 150: | T = +20 °C: 397.3724193 V T = -25 °C: 361.6380309 V |
Voltage for Gain 200: | T = +20 °C: 401.7006315 V T = -25 °C: 365.7865048 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.471487053 V-1 T = -25 °C: 5.556576779 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.839352024 V-1 T = -25 °C: 8.869701017 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 15.59714039 V-1 T = -25 °C: 15.0867639 V-1 |
Break-through voltage: | T = +20 °C: 415.9260098 V T = -25 °C: 379.4676693 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:10:00 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:31:06 CEST | jreher | Updated APD characteristics via API. |
27. Nov 2019 19:58:38 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:24:09 CET | jreher | Updated box and position via API. |
30. Jul 2019 15:15:49 CEST | spankonin | Updated APD batch assignment via API. |
19. Jul 2019 09:18:53 CEST | markus.moritz | |
05. Jul 2019 13:58:29 CEST | jreher | Updated APD location via API. |
24. Jun 2019 13:27:20 CEST | jgrochowski | Updated APD batch assignment via API. |
03. Jan 2019 00:12:11 CET | Tobias | Corrected dark current unit. |
12. Jan 2018 13:12:02 CET | Tobias | Imported from Hamamatsu datasheet. |