Subdetector specification:  
Serial: 2507028038
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2507028038/0820008727
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: blue
   
Manufacturer information:  
Wafer position: F08
Break-through voltage: 412 V
Voltage for Gain 100 (T=+25°C): 383.8 V
Dark current: 7 nA
   
Screening Logistics:  
Available: No
Storage Box: 168
Position in Box: 36
EP1 batch: 21
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jul 2019
Sent for analysis after irradiation: 19. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 16. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 383.4933052 V     T = -25 °C: 347.8774076 V
Voltage for Gain 150: T = +20 °C: 391.3410691 V     T = -25 °C: 355.2334237 V
Voltage for Gain 200: T = +20 °C: 395.7093787 V     T = -25 °C: 359.3577356 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.508426969 V-1     T = -25 °C: 5.051771962 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.860038151 V-1     T = -25 °C: 9.508241165 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.66969569 V-1     T = -25 °C: 15.17600594 V-1
Break-through voltage: T = +20 °C: 411.4300708 V     T = -25 °C: 374.6000008 V
   
Notes:


Version history

Time Author Change comment
16. Feb 2021 12:25:42 CET jreher Updated box and position via API.
15. Feb 2021 15:39:54 CET jreher Assigned to capsule by script
05. Feb 2021 11:09:59 CET jreher Updated box and position via API.
11. Aug 2020 17:31:04 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:58:38 CET jreher Updated APD location via API.
25. Nov 2019 17:24:09 CET jreher Updated box and position via API.
30. Jul 2019 15:15:49 CEST spankonin Updated APD batch assignment via API.
19. Jul 2019 09:13:46 CEST markus.moritz
05. Jul 2019 13:58:29 CEST jreher Updated APD location via API.
24. Jun 2019 13:27:20 CEST jgrochowski Updated APD batch assignment via API.
03. Jan 2019 00:12:11 CET Tobias Corrected dark current unit.
12. Jan 2018 13:12:02 CET Tobias Imported from Hamamatsu datasheet.