RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2507028017 - Archived data from Fri, 29. January 2021 10:23:25 CET


This is all the information about APD 2507028017. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2507028017
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2420027491/2507028017
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: red
   
Manufacturer information:  
Wafer position: C06
Break-through voltage: 414 V
Voltage for Gain 100 (T=+25°C): 384.9 V
Dark current: 6.9 nA
   
Screening Logistics:  
Available: No
Storage Box: 168
Position in Box: 15
EP1 batch: 20
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 02. Jul 2019
Sent for analysis after irradiation: 09. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 04. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 05. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 384.8162533 V     T = -25 °C: 349.4871325 V
Voltage for Gain 150: T = +20 °C: 392.7463618 V     T = -25 °C: 356.9217927 V
Voltage for Gain 200: T = +20 °C: 397.1514611 V     T = -25 °C: 361.059422 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.374495169 V-1     T = -25 °C: 4.784867582 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.597879955 V-1     T = -25 °C: 8.946935109 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.20893428 V-1     T = -25 °C: 16.24986451 V-1
Break-through voltage: T = +20 °C: 412.5267187 V     T = -25 °C: 375.9556778 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:09:56 CET jreher Updated box and position via API.
29. Jan 2021 10:23:25 CET jreher Assigned to capsule by script
06. Oct 2020 16:52:44 CEST jreher Updated box and position via API.
11. Aug 2020 17:31:00 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:58:36 CET jreher Updated APD location via API.
25. Nov 2019 17:24:07 CET jreher Updated box and position via API.
30. Jul 2019 15:15:15 CEST spankonin Updated APD batch assignment via API.
09. Jul 2019 15:51:51 CEST markus.moritz
05. Jul 2019 13:58:27 CEST jreher Updated APD location via API.
24. Jun 2019 13:23:06 CEST jgrochowski Updated APD batch assignment via API.
03. Jan 2019 00:12:11 CET Tobias Corrected dark current unit.
12. Jan 2018 13:12:01 CET Tobias Imported from Hamamatsu datasheet.