RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2506027993 - Archived data from Tue, 11. August 2020 17:30:00 CEST


This is all the information about APD 2506027993. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2506027993
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D12
Break-through voltage: 415 V
Voltage for Gain 100 (T=+25°C): 387.2 V
Dark current: 5.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 177
Position in Box: 48
EP1 batch: 20
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 02. Jul 2019
Sent for analysis after irradiation: 09. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 04. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 05. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 386.8620298 V     T = -25 °C: 352.0372529 V
Voltage for Gain 150: T = +20 °C: 394.8556514 V     T = -25 °C: 359.409522 V
Voltage for Gain 200: T = +20 °C: 399.284816 V     T = -25 °C: 363.5387141 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.382731178 V-1     T = -25 °C: 5.006188153 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.432935304 V-1     T = -25 °C: 9.402884382 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.71346442 V-1     T = -25 °C: 15.2688053 V-1
Break-through voltage: T = +20 °C: 414.2553511 V     T = -25 °C: 378.2423996 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:11:10 CET jreher Updated box and position via API.
11. Aug 2020 17:30:00 CEST jreher Updated APD characteristics via API.
27. Nov 2019 20:00:18 CET jreher Updated APD location via API.
25. Nov 2019 17:24:52 CET jreher Updated box and position via API.
18. Jul 2019 10:26:30 CEST spankonin Updated APD batch assignment via API.
09. Jul 2019 15:43:29 CEST markus.moritz
05. Jul 2019 14:50:16 CEST jreher Updated APD location via API.
24. Jun 2019 13:23:05 CEST jgrochowski Updated APD batch assignment via API.
03. Jan 2019 00:12:10 CET Tobias Corrected dark current unit.
12. Jan 2018 13:12:01 CET Tobias Imported from Hamamatsu datasheet.