Show Hamamatsu Avalanche Photo Diode 2505027933 - Archived data from Tue, 09. July 2019 13:53:10 CEST
This is all the information about APD 2505027933. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2505027933 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum Box 176 |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | C11 |
Break-through voltage: | 413 V |
Voltage for Gain 100 (T=+25°C): | 385 V |
Dark current: | 6.6 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 176 |
Position in Box: | 41 |
EP1 batch: | 18 |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | 02. Jul 2019 |
Sent for analysis after irradiation: | 09. Jul 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 04. Jul 2019 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 05. Jul 2019 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
Break-through voltage: | T = +20 °C: none T = -25 °C: none |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:11:01 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:29:50 CEST | jreher | Updated APD characteristics via API. |
27. Nov 2019 20:00:06 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:24:47 CET | jreher | Updated box and position via API. |
18. Jul 2019 10:27:22 CEST | spankonin | Updated APD batch assignment via API. |
09. Jul 2019 13:53:10 CEST | markus.moritz | |
05. Jul 2019 14:50:07 CEST | jreher | Updated APD location via API. |
24. Jun 2019 13:08:54 CEST | jgrochowski | Updated APD batch assignment via API. |
03. Jan 2019 00:12:08 CET | Tobias | Corrected dark current unit. |
12. Jan 2018 13:12:00 CET | Tobias | Imported from Hamamatsu datasheet. |