RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2505027906 - Archived data from Tue, 11. August 2020 17:29:45 CEST


This is all the information about APD 2505027906. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2505027906
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2412026918/2505027906
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: red
   
Manufacturer information:  
Wafer position: D05
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 380.1 V
Dark current: 5.4 nA
   
Screening Logistics:  
Available: No
Storage Box: 176
Position in Box: 15
EP1 batch: 17
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 02. Jul 2019
Sent for analysis after irradiation: 09. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 04. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 05. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 380.8610834 V     T = -25 °C: 345.3374584 V
Voltage for Gain 150: T = +20 °C: 388.7020076 V     T = -25 °C: 352.7597395 V
Voltage for Gain 200: T = +20 °C: 393.0546462 V     T = -25 °C: 356.9011226 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.719651863 V-1     T = -25 °C: 4.840753369 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.569703428 V-1     T = -25 °C: 9.898890234 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.93528912 V-1     T = -25 °C: 16.01809242 V-1
Break-through voltage: T = +20 °C: 407.913025 V     T = -25 °C: 371.5452253 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:10:59 CET jreher Updated box and position via API.
11. Aug 2020 17:29:45 CEST jreher Updated APD characteristics via API.
31. Mar 2020 08:51:56 CEST jreher Assigned to capsule by script
13. Feb 2020 14:19:55 CET jreher Updated box and position via API.
27. Nov 2019 20:00:05 CET jreher Updated APD location via API.
25. Nov 2019 17:24:45 CET jreher Updated box and position via API.
18. Jul 2019 10:27:56 CEST spankonin Updated APD batch assignment via API.
09. Jul 2019 13:06:18 CEST markus.moritz
05. Jul 2019 14:50:05 CEST jreher Updated APD location via API.
24. Jun 2019 13:05:55 CEST jgrochowski Updated APD batch assignment via API.
03. Jan 2019 00:12:07 CET Tobias Corrected dark current unit.
12. Jan 2018 13:11:59 CET Tobias Imported from Hamamatsu datasheet.