RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2504027882 - Archived data from Tue, 08. December 2020 17:09:29 CET


This is all the information about APD 2504027882. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2504027882
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2504027882/2406026387
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: blue
   
Manufacturer information:  
Wafer position: A09
Break-through voltage: 413 V
Voltage for Gain 100 (T=+25°C): 384.3 V
Dark current: 9.1 nA
   
Screening Logistics:  
Available: No
Storage Box: 176
Position in Box: 2
EP1 batch: 17
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 02. Jul 2019
Sent for analysis after irradiation: 09. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 04. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 05. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 384.0650143 V     T = -25 °C: 348.5572648 V
Voltage for Gain 150: T = +20 °C: 391.9633701 V     T = -25 °C: 356.0324694 V
Voltage for Gain 200: T = +20 °C: 396.3616656 V     T = -25 °C: 360.2216722 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.543102364 V-1     T = -25 °C: 4.638326581 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.016920842 V-1     T = -25 °C: 9.411607738 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.02159952 V-1     T = -25 °C: 14.89129583 V-1
Break-through voltage: T = +20 °C: 409.3210286 V     T = -25 °C: 376.1194096 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:10:57 CET jreher Updated box and position via API.
08. Dec 2020 17:09:29 CET jreher Assigned to capsule by script
06. Oct 2020 16:51:39 CEST jreher Updated box and position via API.
11. Aug 2020 17:29:43 CEST jreher Updated APD characteristics via API.
27. Nov 2019 20:00:04 CET jreher Updated APD location via API.
25. Nov 2019 17:24:44 CET jreher Updated box and position via API.
18. Jul 2019 10:27:55 CEST spankonin Updated APD batch assignment via API.
09. Jul 2019 13:02:21 CEST markus.moritz
05. Jul 2019 14:50:04 CEST jreher Updated APD location via API.
24. Jun 2019 13:05:54 CEST jgrochowski Updated APD batch assignment via API.
03. Jan 2019 00:12:07 CET Tobias Corrected dark current unit.
12. Jan 2018 13:11:59 CET Tobias Imported from Hamamatsu datasheet.