RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2504027880 - Archived data from Tue, 11. August 2020 17:29:42 CEST


This is all the information about APD 2504027880. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2504027880
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: A06
Break-through voltage: 413 V
Voltage for Gain 100 (T=+25°C): 384.4 V
Dark current: 7.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 175
Position in Box: 50
EP1 batch: 16
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 19. Feb 2019
Sent for analysis after irradiation: 01. Apr 2019
Return for assembly: none
   
Irradiation:  
Date: 27. Mar 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 27. Mar 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 384.5766595 V     T = -25 °C: 349.1527446 V
Voltage for Gain 150: T = +20 °C: 392.4265525 V     T = -25 °C: 356.5740663 V
Voltage for Gain 200: T = +20 °C: 396.8073104 V     T = -25 °C: 360.7294395 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.454483451 V-1     T = -25 °C: 4.898197136 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.733877692 V-1     T = -25 °C: 9.105895394 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.38570009 V-1     T = -25 °C: 16.29078596 V-1
Break-through voltage: T = +20 °C: 404.7315768 V     T = -25 °C: 376.3322167 V
   
Notes:


Version history

Time Author Change comment
20. Oct 2021 09:22:45 CEST oafedulidis Assigned to capsule by script
15. Apr 2021 17:01:01 CEST jreher Updated box and position via API.
05. Feb 2021 11:10:55 CET jreher Updated box and position via API.
11. Aug 2020 17:29:42 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:59:56 CET jreher Updated APD location via API.
25. Nov 2019 17:24:43 CET jreher Updated box and position via API.
03. Sep 2019 11:31:37 CEST jgrochowski Updated APD batch assignment via API.
18. Jul 2019 10:27:55 CEST spankonin Updated APD batch assignment via API.
09. Jul 2019 12:51:20 CEST markus.moritz
05. Jul 2019 14:50:00 CEST jreher Updated APD location via API.
21. Jun 2019 15:50:47 CEST jgrochowski Updated APD batch assignment via API.
01. Apr 2019 10:20:24 CEST markus.moritz
03. Jan 2019 00:12:07 CET Tobias Corrected dark current unit.
12. Jan 2018 13:11:59 CET Tobias Imported from Hamamatsu datasheet.