RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2504027874


This is all the information about APD 2504027874. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2504027874
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2504027874/2707030517
Unit: #2174 (barcode 1309020768)
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: blue
   
Manufacturer information:  
Wafer position: E04
Break-through voltage: 411 V
Voltage for Gain 100 (T=+25°C): 382.7 V
Dark current: 4.7 nA
   
Screening Logistics:  
Available: No
Storage Box: 175
Position in Box: 44
EP1 batch: 16
EP1 batch after irradiation: 10100
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 19. Feb 2019
Sent for analysis after irradiation: 01. Apr 2019
Return for assembly: none
   
Irradiation:  
Date: 27. Mar 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 27. Mar 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 382.6664137 V     T = -25 °C: 347.0993354 V
Voltage for Gain 150: T = +20 °C: 390.4688318 V     T = -25 °C: 354.487276 V
Voltage for Gain 200: T = +20 °C: 394.8117519 V     T = -25 °C: 358.6261315 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.423825447 V-1     T = -25 °C: 4.921012188 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.83071641 V-1     T = -25 °C: 9.199245262 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.54863365 V-1     T = -25 °C: 14.66110015 V-1
Break-through voltage: T = +20 °C: 409.8786172 V     T = -25 °C: 373.5290074 V
   
Notes:


Characteristics

Temperature Measurement Notes
No characteristics available!


Upload new characteristic...

Progression of the current during irradiation

Upload time Notes
No data available!


Upload new progression data...

Version history

Time Author Change comment
17. Jun 2021 19:04:19 CEST oafedulidis Assigned to capsule by script
16. Feb 2021 12:27:29 CET jreher Updated box and position via API.
05. Feb 2021 11:10:54 CET jreher Updated box and position via API.
11. Aug 2020 17:29:41 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:59:56 CET jreher Updated APD location via API.
25. Nov 2019 17:24:42 CET jreher Updated box and position via API.
03. Sep 2019 11:31:36 CEST jgrochowski Updated APD batch assignment via API.
18. Jul 2019 10:27:55 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 14:50:00 CEST jreher Updated APD location via API.
21. Jun 2019 15:50:46 CEST jgrochowski Updated APD batch assignment via API.
01. Apr 2019 10:42:57 CEST markus.moritz
03. Jan 2019 00:12:07 CET Tobias Corrected dark current unit.
12. Jan 2018 13:11:59 CET Tobias Imported from Hamamatsu datasheet.