RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2504027828 - Archived data from Fri, 29. January 2021 10:24:38 CET


This is all the information about APD 2504027828. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2504027828
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2514028591/2504027828
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: red
   
Manufacturer information:  
Wafer position: C13
Break-through voltage: 411 V
Voltage for Gain 100 (T=+25°C): 382.2 V
Dark current: 7.8 nA
   
Screening Logistics:  
Available: No
Storage Box: 174
Position in Box: 49
EP1 batch: 15
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 19. Feb 2019
Sent for analysis after irradiation: 01. Apr 2019
Return for assembly: none
   
Irradiation:  
Date: 27. Mar 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 27. Mar 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 382.4517866 V     T = -25 °C: 346.9456594 V
Voltage for Gain 150: T = +20 °C: 390.3100676 V     T = -25 °C: 354.355161 V
Voltage for Gain 200: T = +20 °C: 394.6835412 V     T = -25 °C: 358.5176171 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.479552576 V-1     T = -25 °C: 4.933979868 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.817592303 V-1     T = -25 °C: 9.238019635 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.51814803 V-1     T = -25 °C: 14.58709135 V-1
Break-through voltage: T = +20 °C: 410.2772153 V     T = -25 °C: 373.6662135 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:10:47 CET jreher Updated box and position via API.
29. Jan 2021 10:24:38 CET jreher Assigned to capsule by script
06. Oct 2020 16:52:13 CEST jreher Updated box and position via API.
11. Aug 2020 17:29:32 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:59:45 CET jreher Updated APD location via API.
25. Nov 2019 17:24:38 CET jreher Updated box and position via API.
15. Jul 2019 13:03:31 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 14:49:52 CEST jreher Updated APD location via API.
21. Jun 2019 15:54:21 CEST jgrochowski Updated APD batch assignment via API.
02. Apr 2019 11:09:41 CEST markus.moritz
03. Jan 2019 00:12:05 CET Tobias Corrected dark current unit.
12. Jan 2018 13:11:58 CET Tobias Imported from Hamamatsu datasheet.