Subdetector specification:  
Serial: 2503027790
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D11
Break-through voltage: 411 V
Voltage for Gain 100 (T=+25°C): 382.9 V
Dark current: 3.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 174
Position in Box: 15
EP1 batch: 14
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 19. Feb 2019
Sent for analysis after irradiation: 01. Apr 2019
Return for assembly: none
   
Irradiation:  
Date: 19. Mar 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 27. Mar 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 383.613469 V     T = -25 °C: 348.0575521 V
Voltage for Gain 150: T = +20 °C: 391.4273523 V     T = -25 °C: 355.408862 V
Voltage for Gain 200: T = +20 °C: 395.7819165 V     T = -25 °C: 359.5195036 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.415697315 V-1     T = -25 °C: 5.101986173 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.0293582 V-1     T = -25 °C: 9.527816571 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.20788269 V-1     T = -25 °C: 15.24226481 V-1
Break-through voltage: T = +20 °C: 410.713505 V     T = -25 °C: 373.9474221 V
   
Notes:


Version history

Time Author Change comment
29. Mar 2022 12:35:49 CEST oafedulidis Assigned to capsule by script
17. May 2021 09:16:40 CEST oafedulidis Updated box and position via API.
26. Apr 2021 15:22:58 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:10:43 CET jreher Updated box and position via API.
11. Aug 2020 17:29:26 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:59:43 CET jreher Updated APD location via API.
25. Nov 2019 17:24:35 CET jreher Updated box and position via API.
15. Jul 2019 13:03:13 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 14:49:50 CEST jreher Updated APD location via API.
21. Jun 2019 15:58:10 CEST jgrochowski Updated APD batch assignment via API.
02. Apr 2019 12:03:43 CEST markus.moritz
03. Jan 2019 00:12:04 CET Tobias Corrected dark current unit.
12. Jan 2018 13:11:58 CET Tobias Imported from Hamamatsu datasheet.