Subdetector specification:  
Serial: 2503027745
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2303024341/2503027745
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: red
   
Manufacturer information:  
Wafer position: B05
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 380.1 V
Dark current: 5.2 nA
   
Screening Logistics:  
Available: No
Storage Box: 60
Position in Box: 26
EP1 batch: 12
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 19. Feb 2019
Sent for analysis after irradiation: 01. Apr 2019
Return for assembly: none
   
Irradiation:  
Date: 27. Mar 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 27. Mar 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 380.4067029 V     T = -25 °C: 345.2859193 V
Voltage for Gain 150: T = +20 °C: 388.275438 V     T = -25 °C: 352.6546651 V
Voltage for Gain 200: T = +20 °C: 392.6801284 V     T = -25 °C: 356.7838051 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.492307347 V-1     T = -25 °C: 4.834399521 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.85157102 V-1     T = -25 °C: 9.04510659 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.49868744 V-1     T = -25 °C: 16.22079031 V-1
Break-through voltage: T = +20 °C: 408.2356833 V     T = -25 °C: 371.9102016 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:56:04 CET jreher Updated box and position via API.
03. Feb 2021 18:21:38 CET jreher Updated box and position via API.
11. Aug 2020 17:29:19 CEST jreher Updated APD characteristics via API.
31. Mar 2020 08:53:02 CEST jreher Assigned to capsule by script
13. Feb 2020 14:23:01 CET jreher Updated box and position via API.
27. Nov 2019 19:39:21 CET jreher Updated APD location via API.
25. Nov 2019 17:15:37 CET jreher Updated box and position via API.
15. Jul 2019 13:03:00 CEST spankonin Updated APD batch assignment via API.
12. Jul 2019 13:55:29 CEST jreher Updated APD location via API.
21. Jun 2019 16:13:48 CEST spankonin Updated APD batch assignment via API.
02. Apr 2019 10:19:13 CEST markus.moritz
03. Jan 2019 00:12:03 CET Tobias Corrected dark current unit.
12. Jan 2018 13:11:57 CET Tobias Imported from Hamamatsu datasheet.