RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2503027739 - Archived data from Tue, 11. August 2020 17:29:17 CEST


This is all the information about APD 2503027739. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2503027739
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E04
Break-through voltage: 407 V
Voltage for Gain 100 (T=+25°C): 378.1 V
Dark current: 3.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 60
Position in Box: 12
EP1 batch: 12
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 19. Feb 2019
Sent for analysis after irradiation: 01. Apr 2019
Return for assembly: none
   
Irradiation:  
Date: 27. Mar 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 27. Mar 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 378.2327376 V     T = -25 °C: 343.1400732 V
Voltage for Gain 150: T = +20 °C: 386.0469557 V     T = -25 °C: 350.4617589 V
Voltage for Gain 200: T = +20 °C: 390.4105624 V     T = -25 °C: 354.5743839 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.606344123 V-1     T = -25 °C: 4.966922378 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.105746319 V-1     T = -25 °C: 9.28646232 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.2019031 V-1     T = -25 °C: 14.74785519 V-1
Break-through voltage: T = +20 °C: 405.8196012 V     T = -25 °C: 369.7336839 V
   
Notes:


Version history

Time Author Change comment
26. Oct 2021 15:12:25 CEST oafedulidis Assigned to capsule by script
03. May 2021 15:20:24 CEST oafedulidis Updated box and position via API.
26. Apr 2021 15:22:10 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:56:04 CET jreher Updated box and position via API.
03. Feb 2021 18:21:37 CET jreher Updated box and position via API.
11. Aug 2020 17:29:17 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:39:20 CET jreher Updated APD location via API.
25. Nov 2019 17:15:37 CET jreher Updated box and position via API.
15. Jul 2019 13:03:00 CEST spankonin Updated APD batch assignment via API.
12. Jul 2019 13:55:29 CEST jreher Updated APD location via API.
21. Jun 2019 16:13:48 CEST spankonin Updated APD batch assignment via API.
02. Apr 2019 10:30:37 CEST markus.moritz
03. Jan 2019 00:12:02 CET Tobias Corrected dark current unit.
12. Jan 2018 13:11:57 CET Tobias Imported from Hamamatsu datasheet.