Subdetector specification:  
Serial: 2502027666
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: A10
Break-through voltage: 412 V
Voltage for Gain 100 (T=+25°C): 383.7 V
Dark current: 6.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 59
Position in Box: 37
EP1 batch: 11
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 19. Feb 2019
Sent for analysis after irradiation: 01. Apr 2019
Return for assembly: none
   
Irradiation:  
Date: 27. Mar 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 27. Mar 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 382.9446368 V     T = -25 °C: 348.3760874 V
Voltage for Gain 150: T = +20 °C: 390.9101594 V     T = -25 °C: 355.7312923 V
Voltage for Gain 200: T = +20 °C: 395.3287438 V     T = -25 °C: 359.8459863 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.438753106 V-1     T = -25 °C: 4.790043106 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.420128006 V-1     T = -25 °C: 9.170400287 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.74128218 V-1     T = -25 °C: 14.74551415 V-1
Break-through voltage: T = +20 °C: 405.8656131 V     T = -25 °C: 375.0262526 V
   
Notes:


Version history

Time Author Change comment
16. Nov 2022 10:01:30 CET oafedulidis Assigned to capsule by script
30. Aug 2021 14:07:12 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:55:58 CET jreher Updated box and position via API.
03. Feb 2021 18:21:31 CET jreher Updated box and position via API.
11. Aug 2020 17:29:13 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:39:11 CET jreher Updated APD location via API.
25. Nov 2019 17:15:33 CET jreher Updated box and position via API.
15. Jul 2019 13:02:45 CEST spankonin Updated APD batch assignment via API.
04. Jul 2019 11:13:14 CEST jreher Updated APD location via API.
21. Jun 2019 16:14:20 CEST spankonin Updated APD batch assignment via API.
01. Apr 2019 13:53:34 CEST markus.moritz
03. Jan 2019 00:12:01 CET Tobias Corrected dark current unit.
12. Jan 2018 13:11:56 CET Tobias Imported from Hamamatsu datasheet.