Subdetector specification:  
Serial: 2502027661
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2414027089/2502027661
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: red
   
Manufacturer information:  
Wafer position: G12
Break-through voltage: 407 V
Voltage for Gain 100 (T=+25°C): 381.6 V
Dark current: 3.6 nA
   
Screening Logistics:  
Available: No
Storage Box: 59
Position in Box: 32
EP1 batch: 11
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 19. Feb 2019
Sent for analysis after irradiation: 01. Apr 2019
Return for assembly: none
   
Irradiation:  
Date: 27. Mar 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 27. Mar 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 380.8284588 V     T = -25 °C: 345.9816827 V
Voltage for Gain 150: T = +20 °C: 388.7277138 V     T = -25 °C: 353.3860204 V
Voltage for Gain 200: T = +20 °C: 393.1102431 V     T = -25 °C: 357.551491 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.35371764 V-1     T = -25 °C: 5.004611557 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.458690825 V-1     T = -25 °C: 9.253851159 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.68647204 V-1     T = -25 °C: 14.67034142 V-1
Break-through voltage: T = +20 °C: 403.0789523 V     T = -25 °C: 373.0461767 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:55:57 CET jreher Updated box and position via API.
03. Feb 2021 18:21:31 CET jreher Updated box and position via API.
11. Aug 2020 17:29:11 CEST jreher Updated APD characteristics via API.
31. Mar 2020 08:51:52 CEST jreher Assigned to capsule by script
13. Feb 2020 14:19:56 CET jreher Updated box and position via API.
27. Nov 2019 19:39:10 CET jreher Updated APD location via API.
25. Nov 2019 17:15:33 CET jreher Updated box and position via API.
15. Jul 2019 13:02:33 CEST spankonin Updated APD batch assignment via API.
04. Jul 2019 11:13:13 CEST jreher Updated APD location via API.
21. Jun 2019 16:14:19 CEST spankonin Updated APD batch assignment via API.
01. Apr 2019 14:01:07 CEST markus.moritz
03. Jan 2019 00:12:01 CET Tobias Corrected dark current unit.
12. Jan 2018 13:11:56 CET Tobias Imported from Hamamatsu datasheet.