Show Hamamatsu Avalanche Photo Diode 2502027654 - Archived data from Wed, 03. February 2021 18:21:30 CET


This is all the information about APD 2502027654. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2502027654
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2501027632/2502027654
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: red
   
Manufacturer information:  
Wafer position: E13
Break-through voltage: 410 V
Voltage for Gain 100 (T=+25°C): 380.6 V
Dark current: 3.8 nA
   
Screening Logistics:  
Available: No
Storage Box: 59
Position in Box: 26
EP1 batch: 11
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 19. Feb 2019
Sent for analysis after irradiation: 01. Apr 2019
Return for assembly: none
   
Irradiation:  
Date: 27. Mar 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 27. Mar 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 380.7014415 V     T = -25 °C: 345.4007357 V
Voltage for Gain 150: T = +20 °C: 388.5644048 V     T = -25 °C: 352.8286326 V
Voltage for Gain 200: T = +20 °C: 392.9278119 V     T = -25 °C: 356.9861969 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.410335054 V-1     T = -25 °C: 4.824579881 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.570290964 V-1     T = -25 °C: 9.736931448 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.93543871 V-1     T = -25 °C: 15.5947007 V-1
Break-through voltage: T = +20 °C: 408.8938382 V     T = -25 °C: 372.4212898 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:55:57 CET jreher Updated box and position via API.
03. Feb 2021 18:21:30 CET jreher Updated box and position via API.
11. Aug 2020 17:29:10 CEST jreher Updated APD characteristics via API.
03. Apr 2020 09:44:54 CEST jreher Assigned to capsule by script
13. Feb 2020 14:23:37 CET jreher Updated box and position via API.
27. Nov 2019 19:39:10 CET jreher Updated APD location via API.
25. Nov 2019 17:15:33 CET jreher Updated box and position via API.
15. Jul 2019 13:02:32 CEST spankonin Updated APD batch assignment via API.
04. Jul 2019 11:13:13 CEST jreher Updated APD location via API.
21. Jun 2019 16:14:19 CEST spankonin Updated APD batch assignment via API.
01. Apr 2019 14:32:51 CEST markus.moritz
03. Jan 2019 00:12:01 CET Tobias Corrected dark current unit.
12. Jan 2018 13:11:56 CET Tobias Imported from Hamamatsu datasheet.