RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2502027652 - Archived data from Tue, 11. August 2020 17:29:10 CEST


This is all the information about APD 2502027652. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2502027652
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 0722007042/2502027652
Unit: #1055 (barcode 1309011742)
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: red
   
Manufacturer information:  
Wafer position: D11
Break-through voltage: 410 V
Voltage for Gain 100 (T=+25°C): 381 V
Dark current: 3.9 nA
   
Screening Logistics:  
Available: No
Storage Box: 59
Position in Box: 24
EP1 batch: 11
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 19. Feb 2019
Sent for analysis after irradiation: 01. Apr 2019
Return for assembly: none
   
Irradiation:  
Date: 27. Mar 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 27. Mar 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 380.8125962 V     T = -25 °C: 345.663745 V
Voltage for Gain 150: T = +20 °C: 388.7331037 V     T = -25 °C: 353.0582776 V
Voltage for Gain 200: T = +20 °C: 393.1192457 V     T = -25 °C: 357.2006055 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.624015096 V-1     T = -25 °C: 4.710450527 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.318413034 V-1     T = -25 °C: 9.581360851 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.5798406 V-1     T = -25 °C: 15.33495234 V-1
Break-through voltage: T = +20 °C: 409.3897698 V     T = -25 °C: 372.7497247 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:55:56 CET jreher Updated box and position via API.
03. Feb 2021 18:21:30 CET jreher Updated box and position via API.
11. Aug 2020 17:29:10 CEST jreher Updated APD characteristics via API.
03. Apr 2020 09:46:12 CEST jreher Assigned to capsule by script
13. Feb 2020 14:23:54 CET jreher Updated box and position via API.
27. Nov 2019 19:39:10 CET jreher Updated APD location via API.
25. Nov 2019 17:15:32 CET jreher Updated box and position via API.
15. Jul 2019 13:02:32 CEST spankonin Updated APD batch assignment via API.
04. Jul 2019 11:13:12 CEST jreher Updated APD location via API.
21. Jun 2019 16:14:19 CEST spankonin Updated APD batch assignment via API.
01. Apr 2019 14:38:16 CEST markus.moritz
03. Jan 2019 00:12:00 CET Tobias Corrected dark current unit.
12. Jan 2018 13:11:56 CET Tobias Imported from Hamamatsu datasheet.