Show Hamamatsu Avalanche Photo Diode 2501027599 - Archived data from Wed, 07. October 2020 12:12:58 CEST
This is all the information about APD 2501027599. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2501027599 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | assigned to 2501027599/0819008704 |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | blue |
Manufacturer information: | |
Wafer position: | F02 |
Break-through voltage: | 410 V |
Voltage for Gain 100 (T=+25°C): | 381.6 V |
Dark current: | 4.7 nA |
Screening Logistics: | |
Available: | No |
Storage Box: | 58 |
Position in Box: | 27 |
EP1 batch: | 9 |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | 19. Feb 2019 |
Sent for analysis after irradiation: | 01. Apr 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 27. Mar 2019 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 27. Mar 2019 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 381.3066072 V T = -25 °C: 346.7596614 V |
Voltage for Gain 150: | T = +20 °C: 389.3313015 V T = -25 °C: 354.145739 V |
Voltage for Gain 200: | T = +20 °C: 393.8136179 V T = -25 °C: 358.2830546 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.560611875 V-1 T = -25 °C: 4.949819902 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.788156792 V-1 T = -25 °C: 9.690507555 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 13.75957846 V-1 T = -25 °C: 15.71505978 V-1 |
Break-through voltage: | T = +20 °C: 409.5834904 V T = -25 °C: 373.1328793 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:55:49 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:21:23 CET | jreher | Updated box and position via API. |
07. Oct 2020 12:12:58 CEST | jreher | Assigned to capsule by script |
17. Aug 2020 15:53:26 CEST | jreher | Updated box and position via API. |
11. Aug 2020 17:29:02 CEST | jreher | Updated APD characteristics via API. |
27. Nov 2019 19:38:59 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:15:28 CET | jreher | Updated box and position via API. |
15. Jul 2019 13:02:18 CEST | spankonin | Updated APD batch assignment via API. |
04. Jul 2019 11:13:05 CEST | jreher | Updated APD location via API. |
21. Jun 2019 16:15:41 CEST | spankonin | Updated APD batch assignment via API. |
01. Apr 2019 13:29:46 CEST | markus.moritz | |
03. Jan 2019 00:11:59 CET | Tobias | Corrected dark current unit. |
12. Jan 2018 13:11:55 CET | Tobias | Imported from Hamamatsu datasheet. |