Show Hamamatsu Avalanche Photo Diode 2501027593 - Archived data from Mon, 26. April 2021 14:30:12 CEST


This is all the information about APD 2501027593. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2501027593
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C08
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 380.4 V
Dark current: 5.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 58
Position in Box: 9
EP1 batch: 9
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 19. Feb 2019
Sent for analysis after irradiation: 01. Apr 2019
Return for assembly: none
   
Irradiation:  
Date: 27. Mar 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 27. Mar 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 380.1740777 V     T = -25 °C: 345.2299475 V
Voltage for Gain 150: T = +20 °C: 388.1203316 V     T = -25 °C: 352.6365993 V
Voltage for Gain 200: T = +20 °C: 392.5514317 V     T = -25 °C: 356.7653026 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.60256688 V-1     T = -25 °C: 4.90140228 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.013716446 V-1     T = -25 °C: 9.159274278 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.23625746 V-1     T = -25 °C: 14.73622973 V-1
Break-through voltage: T = +20 °C: 408.419013 V     T = -25 °C: 371.8179235 V
   
Notes:


Version history

Time Author Change comment
27. Oct 2021 14:14:21 CEST oafedulidis Assigned to capsule by script
28. Apr 2021 13:28:56 CEST oafedulidis Updated box and position via API.
26. Apr 2021 14:30:12 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:55:48 CET jreher Updated box and position via API.
03. Feb 2021 18:21:22 CET jreher Updated box and position via API.
11. Aug 2020 17:29:01 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:38:58 CET jreher Updated APD location via API.
25. Nov 2019 17:15:27 CET jreher Updated box and position via API.
15. Jul 2019 13:02:17 CEST spankonin Updated APD batch assignment via API.
04. Jul 2019 11:13:05 CEST jreher Updated APD location via API.
21. Jun 2019 16:15:40 CEST spankonin Updated APD batch assignment via API.
01. Apr 2019 13:42:41 CEST markus.moritz
03. Jan 2019 00:11:59 CET Tobias Corrected dark current unit.
12. Jan 2018 13:11:55 CET Tobias Imported from Hamamatsu datasheet.