Subdetector specification:  
Serial: 2501027588
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 1910021018/2501027588
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: red
   
Manufacturer information:  
Wafer position: G09
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 379.9 V
Dark current: 4.8 nA
   
Screening Logistics:  
Available: No
Storage Box: 58
Position in Box: 16
EP1 batch: 9
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 19. Feb 2019
Sent for analysis after irradiation: 01. Apr 2019
Return for assembly: none
   
Irradiation:  
Date: 27. Mar 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 27. Mar 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 379.4851359 V     T = -25 °C: 344.3539132 V
Voltage for Gain 150: T = +20 °C: 387.2923552 V     T = -25 °C: 351.7334826 V
Voltage for Gain 200: T = +20 °C: 391.6534837 V     T = -25 °C: 355.8620637 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.530765524 V-1     T = -25 °C: 4.863345756 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.855426803 V-1     T = -25 °C: 8.980156716 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.87983369 V-1     T = -25 °C: 16.12535521 V-1
Break-through voltage: T = +20 °C: 406.9958821 V     T = -25 °C: 371.2617207 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:55:48 CET jreher Updated box and position via API.
03. Feb 2021 18:21:21 CET jreher Updated box and position via API.
11. Aug 2020 17:29:00 CEST jreher Updated APD characteristics via API.
31. Mar 2020 08:52:38 CEST jreher Assigned to capsule by script
13. Feb 2020 14:21:51 CET jreher Updated box and position via API.
27. Nov 2019 19:38:58 CET jreher Updated APD location via API.
25. Nov 2019 17:15:27 CET jreher Updated box and position via API.
15. Jul 2019 13:02:06 CEST spankonin Updated APD batch assignment via API.
04. Jul 2019 11:13:04 CEST jreher Updated APD location via API.
21. Jun 2019 16:15:40 CEST spankonin Updated APD batch assignment via API.
01. Apr 2019 13:52:03 CEST markus.moritz
01. Apr 2019 13:51:38 CEST markus.moritz
03. Jan 2019 00:11:58 CET Tobias Corrected dark current unit.
12. Jan 2018 13:11:55 CET Tobias Imported from Hamamatsu datasheet.