Subdetector specification:  
Serial: 2501027587
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E13
Break-through voltage: 414 V
Voltage for Gain 100 (T=+25°C): 385.2 V
Dark current: 6.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 58
Position in Box: 15
EP1 batch: 9
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 19. Feb 2019
Sent for analysis after irradiation: 01. Apr 2019
Return for assembly: none
   
Irradiation:  
Date: 27. Mar 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 27. Mar 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 385.0318135 V     T = -25 °C: 349.4396927 V
Voltage for Gain 150: T = +20 °C: 392.9436763 V     T = -25 °C: 356.9188786 V
Voltage for Gain 200: T = +20 °C: 397.3469055 V     T = -25 °C: 361.1211067 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.609621744 V-1     T = -25 °C: 4.658598342 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.046368578 V-1     T = -25 °C: 9.525203438 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.22626885 V-1     T = -25 °C: 15.25342034 V-1
Break-through voltage: T = +20 °C: 413.1018283 V     T = -25 °C: 376.8666204 V
   
Notes:


Version history

Time Author Change comment
26. Oct 2021 10:34:26 CEST oafedulidis Assigned to capsule by script
15. Apr 2021 17:01:24 CEST jreher Updated box and position via API.
05. Feb 2021 10:55:48 CET jreher Updated box and position via API.
03. Feb 2021 18:21:21 CET jreher Updated box and position via API.
11. Aug 2020 17:28:59 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:38:58 CET jreher Updated APD location via API.
25. Nov 2019 17:15:27 CET jreher Updated box and position via API.
15. Jul 2019 13:02:06 CEST spankonin Updated APD batch assignment via API.
04. Jul 2019 11:13:04 CEST jreher Updated APD location via API.
21. Jun 2019 16:15:40 CEST spankonin Updated APD batch assignment via API.
01. Apr 2019 13:53:32 CEST markus.moritz
03. Jan 2019 00:11:58 CET Tobias Corrected dark current unit.
12. Jan 2018 13:11:55 CET Tobias Imported from Hamamatsu datasheet.