Subdetector specification:  
Serial: 2501027584
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: A09
Break-through voltage: 417 V
Voltage for Gain 100 (T=+25°C): 388.4 V
Dark current: 8.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 58
Position in Box: 6
EP1 batch: 9
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 19. Feb 2019
Sent for analysis after irradiation: 01. Apr 2019
Return for assembly: none
   
Irradiation:  
Date: 27. Mar 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 27. Mar 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 388.8516419 V     T = -25 °C: 353.1600194 V
Voltage for Gain 150: T = +20 °C: 396.8078833 V     T = -25 °C: 360.7521413 V
Voltage for Gain 200: T = +20 °C: 401.2171967 V     T = -25 °C: 364.9856184 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.666045798 V-1     T = -25 °C: 4.743962989 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.158171222 V-1     T = -25 °C: 9.668016227 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.58321692 V-1     T = -25 °C: 15.41280251 V-1
Break-through voltage: T = +20 °C: 415.8535714 V     T = -25 °C: 379.7582372 V
   
Notes:


Version history

Time Author Change comment
11. Jul 2022 14:23:43 CEST oafedulidis Assigned to capsule by script
27. Aug 2021 10:29:49 CEST oafedulidis Updated box and position via API.
26. Apr 2021 14:30:11 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:55:47 CET jreher Updated box and position via API.
03. Feb 2021 18:21:21 CET jreher Updated box and position via API.
11. Aug 2020 17:28:59 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:38:58 CET jreher Updated APD location via API.
25. Nov 2019 17:15:27 CET jreher Updated box and position via API.
15. Jul 2019 13:02:05 CEST spankonin Updated APD batch assignment via API.
04. Jul 2019 11:13:04 CEST jreher Updated APD location via API.
21. Jun 2019 16:15:40 CEST spankonin Updated APD batch assignment via API.
01. Apr 2019 13:57:11 CEST markus.moritz
03. Jan 2019 00:11:58 CET Tobias Corrected dark current unit.
12. Jan 2018 13:11:55 CET Tobias Imported from Hamamatsu datasheet.