Show Hamamatsu Avalanche Photo Diode 2501027581 - Archived data from Wed, 27. November 2019 19:38:57 CET
This is all the information about APD 2501027581. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2501027581 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | B10 |
Break-through voltage: | 413 V |
Voltage for Gain 100 (T=+25°C): | 385 V |
Dark current: | 6.9 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 58 |
Position in Box: | 4 |
EP1 batch: | 9 |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | 19. Feb 2019 |
Sent for analysis after irradiation: | 01. Feb 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 27. Mar 2019 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 27. Mar 2019 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
Break-through voltage: | T = +20 °C: none T = -25 °C: none |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
25. Sep 2021 15:57:26 CEST | oafedulidis | Assigned to capsule by script |
17. May 2021 09:17:17 CEST | oafedulidis | Updated box and position via API. |
26. Apr 2021 14:30:11 CEST | oafedulidis | Updated box and position via API. |
05. Feb 2021 10:55:47 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:21:21 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:28:58 CEST | jreher | Updated APD characteristics via API. |
27. Nov 2019 19:38:57 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:15:26 CET | jreher | Updated box and position via API. |
15. Jul 2019 13:02:05 CEST | spankonin | Updated APD batch assignment via API. |
04. Jul 2019 11:13:04 CEST | jreher | Updated APD location via API. |
21. Jun 2019 16:15:40 CEST | spankonin | Updated APD batch assignment via API. |
01. Apr 2019 14:02:02 CEST | markus.moritz | |
03. Jan 2019 00:11:58 CET | Tobias | Corrected dark current unit. |
12. Jan 2018 13:11:55 CET | Tobias | Imported from Hamamatsu datasheet. |