RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2501027563 - Archived data from Wed, 16. June 2021 16:02:39 CEST


This is all the information about APD 2501027563. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2501027563
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E08
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 379 V
Dark current: 4.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 27
Position in Box: 26
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jan 2019
Sent for analysis after irradiation: 28. Jan 2019
Return for assembly: none
   
Irradiation:  
Date: 21. Jan 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 22. Jan 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 379.4462959 V     T = -25 °C: 344.3121753 V
Voltage for Gain 150: T = +20 °C: 387.3087833 V     T = -25 °C: 351.7139458 V
Voltage for Gain 200: T = +20 °C: 391.6985448 V     T = -25 °C: 355.8717355 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.456826219 V-1     T = -25 °C: 4.721753713 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.09454927 V-1     T = -25 °C: 9.022313557 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.32076643 V-1     T = -25 °C: 16.2588362 V-1
Break-through voltage: T = +20 °C: 407.107612 V     T = -25 °C: 370.7942393 V
   
Notes:


Version history

Time Author Change comment
16. Nov 2021 09:41:57 CET oafedulidis Assigned to capsule by script
16. Jun 2021 16:02:39 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:58:56 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:51:46 CEST oafedulidis Updated box and position via API.
05. May 2021 14:07:23 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:51:21 CET jreher Updated box and position via API.
03. Feb 2021 18:17:27 CET jreher Updated box and position via API.
11. Aug 2020 17:24:10 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:34:18 CET jreher Updated APD location via API.
25. Nov 2019 17:13:02 CET jreher Updated box and position via API.
04. Jul 2019 11:09:54 CEST jreher Updated APD location via API.
12. Jun 2019 16:47:27 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:32:22 CEST jreher Updated APD batch assignment via API.
28. Jan 2019 12:18:08 CET markus.moritz
03. Jan 2019 00:11:57 CET Tobias Corrected dark current unit.
12. Jan 2018 13:11:55 CET Tobias Imported from Hamamatsu datasheet.