RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2420027507 - Archived data from Tue, 11. August 2020 17:24:02 CEST


This is all the information about APD 2420027507. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2420027507
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D09
Break-through voltage: 405 V
Voltage for Gain 100 (T=+25°C): 376.6 V
Dark current: 4.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 27
Position in Box: 1
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jan 2019
Sent for analysis after irradiation: 28. Jan 2019
Return for assembly: none
   
Irradiation:  
Date: 21. Jan 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 22. Jan 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 376.5605844 V     T = -25 °C: 341.4549743 V
Voltage for Gain 150: T = +20 °C: 384.3707799 V     T = -25 °C: 348.7873143 V
Voltage for Gain 200: T = +20 °C: 388.768177 V     T = -25 °C: 352.8501962 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.532408214 V-1     T = -25 °C: 4.909206714 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.293747136 V-1     T = -25 °C: 9.221326318 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.33872602 V-1     T = -25 °C: 16.14043211 V-1
Break-through voltage: T = +20 °C: 404.6815404 V     T = -25 °C: 368.2614771 V
   
Notes:


Version history

Time Author Change comment
05. May 2021 14:07:21 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:51:17 CET jreher Updated box and position via API.
03. Feb 2021 18:17:22 CET jreher Updated box and position via API.
11. Aug 2020 17:24:02 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:34:15 CET jreher Updated APD location via API.
25. Nov 2019 17:12:58 CET jreher Updated box and position via API.
04. Jul 2019 11:09:51 CEST jreher Updated APD location via API.
12. Jun 2019 16:47:23 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:32:18 CEST jreher Updated APD batch assignment via API.
28. Jan 2019 12:08:46 CET markus.moritz
03. Jan 2019 00:11:56 CET Tobias Corrected dark current unit.