Serial: 2419027444
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C12
Break-through voltage: 407 V
Voltage for Gain 100 (T=+25°C): 377.9 V
Dark current: 4.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 26
Position in Box: 6
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jan 2019
Sent for analysis after irradiation: 28. Jan 2019
Return for assembly: none
   
Irradiation:  
Date: 21. Jan 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 22. Jan 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 377.9772044 V     T = -25 °C: 342.8125659 V
Voltage for Gain 150: T = +20 °C: 385.8232205 V     T = -25 °C: 350.1850463 V
Voltage for Gain 200: T = +20 °C: 390.1947946 V     T = -25 °C: 354.3289883 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.53415222 V-1     T = -25 °C: 4.892913509 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.715213561 V-1     T = -25 °C: 9.790195779 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.71951223 V-1     T = -25 °C: 15.25343554 V-1
Break-through voltage: T = +20 °C: 405.8777169 V     T = -25 °C: 369.7218614 V
   
Notes:


Version history

Time Author Change comment
21. Apr 2021 14:49:11 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:51:09 CET jreher Updated box and position via API.
03. Feb 2021 18:17:15 CET jreher Updated box and position via API.
11. Aug 2020 17:23:54 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:34:04 CET jreher Updated APD location via API.
25. Nov 2019 17:12:54 CET jreher Updated box and position via API.
04. Jul 2019 11:09:44 CEST jreher Updated APD location via API.
12. Jun 2019 16:47:20 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:32:15 CEST jreher Updated APD batch assignment via API.
28. Jan 2019 12:28:08 CET markus.moritz
03. Jan 2019 00:11:54 CET Tobias Corrected dark current unit.
12. Jan 2018 13:11:53 CET Tobias Imported from Hamamatsu datasheet.