RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2419027428 - Archived data from Tue, 11. August 2020 17:23:51 CEST


This is all the information about APD 2419027428. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2419027428
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2401025923/2419027428
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: red
   
Manufacturer information:  
Wafer position: E04
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 381.5 V
Dark current: 2.8 nA
   
Screening Logistics:  
Available: No
Storage Box: 25
Position in Box: 42
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jan 2019
Sent for analysis after irradiation: 28. Jan 2019
Return for assembly: none
   
Irradiation:  
Date: 21. Jan 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 22. Jan 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 382.0293085 V     T = -25 °C: 346.5244622 V
Voltage for Gain 150: T = +20 °C: 389.8843044 V     T = -25 °C: 353.8839838 V
Voltage for Gain 200: T = +20 °C: 394.2076515 V     T = -25 °C: 358.0496329 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.55417167 V-1     T = -25 °C: 4.868366105 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.58188557 V-1     T = -25 °C: 9.746778152 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.65402266 V-1     T = -25 °C: 14.56520545 V-1
Break-through voltage: T = +20 °C: 408.5958919 V     T = -25 °C: 372.958782 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:51:05 CET jreher Updated box and position via API.
03. Feb 2021 18:17:12 CET jreher Updated box and position via API.
11. Aug 2020 17:23:51 CEST jreher Updated APD characteristics via API.
31. Mar 2020 08:53:16 CEST jreher Assigned to capsule by script
13. Feb 2020 14:22:31 CET jreher Updated box and position via API.
13. Feb 2020 14:22:19 CET jreher Updated box and position via API.
27. Nov 2019 19:33:56 CET jreher Updated APD location via API.
25. Nov 2019 17:12:52 CET jreher Updated box and position via API.
04. Jul 2019 11:09:38 CEST jreher Updated APD location via API.
12. Jun 2019 16:47:18 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:32:13 CEST jreher Updated APD batch assignment via API.
28. Jan 2019 12:59:45 CET markus.moritz
03. Jan 2019 00:11:54 CET Tobias Corrected dark current unit.
12. Jan 2018 13:11:53 CET Tobias Imported from Hamamatsu datasheet.