RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0722007040 - Archived data from Fri, 05. February 2021 11:12:03 CET


This is all the information about APD 0722007040. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0722007040
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G07
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 379.8 V
Dark current: 17.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 184
Position in Box: 23
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 18. Apr 2019
Sent for analysis after irradiation: 09. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 04. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 05. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 380.2040504 V     T = -25 °C: 344.9981977 V
Voltage for Gain 150: T = +20 °C: 387.9672299 V     T = -25 °C: 352.2569726 V
Voltage for Gain 200: T = +20 °C: 392.2605097 V     T = -25 °C: 356.3245784 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.62094969 V-1     T = -25 °C: 5.093517403 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.441037516 V-1     T = -25 °C: 9.871143491 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.16340154 V-1     T = -25 °C: 15.77367429 V-1
Break-through voltage: T = +20 °C: 400.8422494 V     T = -25 °C: 371.4000557 V
   
Notes:


Version history

Time Author Change comment
10. Jun 2022 12:15:39 CEST oafedulidis Assigned to capsule by script
27. Aug 2021 10:30:48 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:12:03 CET jreher Updated box and position via API.
11. Aug 2020 17:30:44 CEST jreher Updated APD characteristics via API.
27. Nov 2019 20:01:34 CET jreher Updated APD location via API.
25. Nov 2019 17:25:23 CET jreher Updated box and position via API.
13. Aug 2019 12:20:13 CEST jreher Updated APD location via API.
22. Jul 2019 10:52:55 CEST spankonin Updated APD batch assignment via API.
10. Jul 2019 13:18:49 CEST markus.moritz
22. Jun 2016 15:22:28 CEST Tobias Imported from Hamamatsu datasheet.