RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2417027260 - Archived data from Tue, 31. March 2020 08:44:09 CEST


This is all the information about APD 2417027260. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2417027260
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2417027260/2413026944
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: blue
   
Manufacturer information:  
Wafer position: E01
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 381.5 V
Dark current: 3.3 nA
   
Screening Logistics:  
Available: No
Storage Box: 22
Position in Box: 49
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jan 2019
Sent for analysis after irradiation: 25. Jan 2019
Return for assembly: none
   
Irradiation:  
Date: 21. Jan 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 22. Jan 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 150: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 200: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 100: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 150: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 200: T = +20 °C: none     T = -25 °C: none
Break-through voltage: T = +20 °C: none     T = -25 °C: none
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:50:41 CET jreher Updated box and position via API.
03. Feb 2021 18:16:50 CET jreher Updated box and position via API.
11. Aug 2020 17:23:23 CEST jreher Updated APD characteristics via API.
31. Mar 2020 08:44:09 CEST jreher Assigned to capsule by script
13. Feb 2020 15:25:30 CET jreher Updated box and position via API.
27. Nov 2019 19:33:23 CET jreher Updated APD location via API.
25. Nov 2019 17:12:39 CET jreher Updated box and position via API.
04. Jul 2019 11:09:14 CEST jreher Updated APD location via API.
12. Jun 2019 16:47:06 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:32:00 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:12:05 CEST jreher Updated APD batch assignment via API.
25. Jan 2019 10:38:32 CET markus.moritz
03. Jan 2019 00:11:49 CET Tobias Corrected dark current unit.
12. Jan 2018 13:11:50 CET Tobias Imported from Hamamatsu datasheet.