RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2416027219 - Archived data from Wed, 03. February 2021 18:16:47 CET


This is all the information about APD 2416027219. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2416027219
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2416027219/2010022200
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: blue
   
Manufacturer information:  
Wafer position: F12
Break-through voltage: 410 V
Voltage for Gain 100 (T=+25°C): 381.5 V
Dark current: 5 nA
   
Screening Logistics:  
Available: No
Storage Box: 22
Position in Box: 27
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jan 2019
Sent for analysis after irradiation: 25. Jan 2019
Return for assembly: none
   
Irradiation:  
Date: 21. Jan 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 22. Jan 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.7937363 V     T = -25 °C: 346.1634932 V
Voltage for Gain 150: T = +20 °C: 389.6055716 V     T = -25 °C: 353.6019328 V
Voltage for Gain 200: T = +20 °C: 393.9383673 V     T = -25 °C: 357.7532141 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.97170087 V-1     T = -25 °C: 4.697739077 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.482454908 V-1     T = -25 °C: 9.839298995 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.6063334 V-1     T = -25 °C: 15.40724087 V-1
Break-through voltage: T = +20 °C: 409.2101856 V     T = -25 °C: 373.0024998 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:50:38 CET jreher Updated box and position via API.
03. Feb 2021 18:16:47 CET jreher Updated box and position via API.
11. Aug 2020 17:23:22 CEST jreher Updated APD characteristics via API.
03. Apr 2020 09:47:23 CEST jreher Assigned to capsule by script
20. Feb 2020 13:34:18 CET jreher Updated box and position via API.
27. Nov 2019 19:33:21 CET jreher Updated APD location via API.
25. Nov 2019 17:12:37 CET jreher Updated box and position via API.
04. Jul 2019 11:09:12 CEST jreher Updated APD location via API.
12. Jun 2019 16:47:05 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:32:00 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:12:05 CEST jreher Updated APD batch assignment via API.
25. Jan 2019 10:42:40 CET markus.moritz
03. Jan 2019 00:11:48 CET Tobias Corrected dark current unit.
12. Jan 2018 13:11:50 CET Tobias Imported from Hamamatsu datasheet.