Subdetector specification:  
Serial: 2416027169
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F10
Break-through voltage: 406 V
Voltage for Gain 100 (T=+25°C): 377.6 V
Dark current: 5.2 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 21
Position in Box: 28
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jan 2019
Sent for analysis after irradiation: 25. Jan 2019
Return for assembly: none
   
Irradiation:  
Date: 21. Jan 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 22. Jan 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 378.0092724 V     T = -25 °C: 342.96721 V
Voltage for Gain 150: T = +20 °C: 385.8191867 V     T = -25 °C: 350.3335727 V
Voltage for Gain 200: T = +20 °C: 390.1769231 V     T = -25 °C: 354.4780715 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.512725011 V-1     T = -25 °C: 4.792668809 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.592486271 V-1     T = -25 °C: 9.51143408 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.4367697 V-1     T = -25 °C: 14.67199741 V-1
Break-through voltage: T = +20 °C: 405.71479 V     T = -25 °C: 369.5399306 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:50:31 CET jreher Updated box and position via API.
03. Feb 2021 18:16:39 CET jreher Updated box and position via API.
11. Aug 2020 17:23:09 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:33:10 CET jreher Updated APD location via API.
25. Nov 2019 17:12:33 CET jreher Updated box and position via API.
04. Jul 2019 11:09:04 CEST jreher Updated APD location via API.
12. Jun 2019 16:46:59 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:31:53 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:10:20 CEST jreher Updated APD batch assignment via API.
25. Jan 2019 14:00:29 CET markus.moritz
03. Jan 2019 00:11:46 CET Tobias Corrected dark current unit.
12. Jan 2018 13:11:49 CET Tobias Imported from Hamamatsu datasheet.