RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2415027120 - Archived data from Tue, 11. August 2020 17:23:01 CEST


This is all the information about APD 2415027120. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2415027120
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F10
Break-through voltage: 403 V
Voltage for Gain 100 (T=+25°C): 375.2 V
Dark current: 5.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 238
Position in Box: 41
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jan 2019
Sent for analysis after irradiation: 25. Jan 2019
Return for assembly: none
   
Irradiation:  
Date: 21. Jan 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 22. Jan 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 375.0814678 V     T = -25 °C: 340.0638604 V
Voltage for Gain 150: T = +20 °C: 382.7785728 V     T = -25 °C: 347.3531441 V
Voltage for Gain 200: T = +20 °C: 387.1218423 V     T = -25 °C: 351.4189224 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.471853071 V-1     T = -25 °C: 5.430016365 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.053734707 V-1     T = -25 °C: 8.573915671 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.93824222 V-1     T = -25 °C: 16.03950614 V-1
Break-through voltage: T = +20 °C: 402.7034865 V     T = -25 °C: 366.5604245 V
   
Notes:


Version history

Time Author Change comment
07. Feb 2022 10:46:36 CET oafedulidis Assigned to capsule by script
16. Jun 2021 16:04:25 CEST oafedulidis Updated box and position via API.
16. Jun 2021 16:00:38 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:53:19 CEST oafedulidis Updated box and position via API.
26. Apr 2021 15:22:36 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:50:23 CET jreher Updated box and position via API.
03. Feb 2021 18:16:32 CET jreher Updated box and position via API.
11. Aug 2020 17:23:01 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:32:59 CET jreher Updated APD location via API.
25. Nov 2019 17:12:28 CET jreher Updated box and position via API.
04. Jul 2019 11:08:56 CEST jreher Updated APD location via API.
12. Jun 2019 16:46:55 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:31:50 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:10:10 CEST jreher Updated APD batch assignment via API.
25. Jan 2019 11:06:54 CET markus.moritz
03. Jan 2019 00:11:45 CET Tobias Corrected dark current unit.
12. Jan 2018 13:11:48 CET Tobias Imported from Hamamatsu datasheet.