RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2415027117 - Archived data from Mon, 26. April 2021 15:22:36 CEST


This is all the information about APD 2415027117. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2415027117
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B07
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 379 V
Dark current: 6.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 238
Position in Box: 40
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 379.7303218 V     T = -25 °C: 344.3062241 V
Voltage for Gain 150: T = +20 °C: 387.4439027 V     T = -25 °C: 351.6507392 V
Voltage for Gain 200: T = +20 °C: 391.7341135 V     T = -25 °C: 355.71001 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.836326008 V-1     T = -25 °C: 4.789046426 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.478011841 V-1     T = -25 °C: 9.737781157 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.78990345 V-1     T = -25 °C: 15.97379996 V-1
Break-through voltage: T = +20 °C: 407.095789 V     T = -25 °C: 370.9453788 V
   
Notes:


Version history

Time Author Change comment
25. Sep 2021 16:12:07 CEST oafedulidis Assigned to capsule by script
03. May 2021 15:18:13 CEST oafedulidis Updated box and position via API.
26. Apr 2021 15:22:36 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:50:23 CET jreher Updated box and position via API.
03. Feb 2021 18:16:32 CET jreher Updated box and position via API.
11. Aug 2020 17:23:00 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:32:59 CET jreher Updated APD location via API.
25. Nov 2019 17:12:28 CET jreher Updated box and position via API.
04. Jul 2019 11:08:56 CEST jreher Updated APD location via API.
12. Jun 2019 16:46:55 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:31:49 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:10:10 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:11:44 CET Tobias Corrected dark current unit.
12. Jan 2018 13:11:48 CET Tobias Imported from Hamamatsu datasheet.