Show Hamamatsu Avalanche Photo Diode 2415027110 - Archived data from Fri, 05. February 2021 10:50:22 CET
This is all the information about APD 2415027110. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2415027110 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | D10 |
Break-through voltage: | 404 V |
Voltage for Gain 100 (T=+25°C): | 375.8 V |
Dark current: | 4.4 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 238 |
Position in Box: | 33 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | none |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 376.588666 V T = -25 °C: 341.7952635 V |
Voltage for Gain 150: | T = +20 °C: 384.3310768 V T = -25 °C: 349.0712496 V |
Voltage for Gain 200: | T = +20 °C: 388.6623919 V T = -25 °C: 353.1542908 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.649074602 V-1 T = -25 °C: 4.884796066 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.005976296 V-1 T = -25 °C: 9.800368652 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 15.26982193 V-1 T = -25 °C: 15.21754086 V-1 |
Break-through voltage: | T = +20 °C: 403.6081643 V T = -25 °C: 367.65779 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
26. Apr 2021 15:22:35 CEST | oafedulidis | Updated box and position via API. |
05. Feb 2021 10:50:22 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:16:31 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:22:58 CEST | jreher | Updated APD characteristics via API. |
27. Nov 2019 19:32:59 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:12:27 CET | jreher | Updated box and position via API. |
04. Jul 2019 11:08:55 CEST | jreher | Updated APD location via API. |
12. Jun 2019 16:46:53 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 16:31:48 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 15:10:01 CEST | jreher | Updated APD batch assignment via API. |
03. Jan 2019 00:11:44 CET | Tobias | Corrected dark current unit. |
12. Jan 2018 13:11:48 CET | Tobias | Imported from Hamamatsu datasheet. |