Show Hamamatsu Avalanche Photo Diode 2414027082 - Archived data from Wed, 27. November 2019 19:32:57 CET
This is all the information about APD 2414027082. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2414027082 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | C06 |
Break-through voltage: | 409 V |
Voltage for Gain 100 (T=+25°C): | 380.2 V |
Dark current: | 10.5 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 20 |
Position in Box: | 1 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | none |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
Break-through voltage: | T = +20 °C: none T = -25 °C: none |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:50:20 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:16:29 CET | jreher | Updated box and position via API. |
07. Oct 2020 14:22:36 CEST | jreher | Assigned to capsule by script |
17. Aug 2020 15:53:52 CEST | jreher | Updated box and position via API. |
11. Aug 2020 17:22:55 CEST | jreher | Updated APD characteristics via API. |
27. Nov 2019 19:32:57 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:12:26 CET | jreher | Updated box and position via API. |
04. Jul 2019 11:08:53 CEST | jreher | Updated APD location via API. |
12. Jun 2019 16:46:52 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 16:31:47 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 15:10:00 CEST | jreher | Updated APD batch assignment via API. |
03. Jan 2019 00:11:44 CET | Tobias | Corrected dark current unit. |
12. Jan 2018 13:11:48 CET | Tobias | Imported from Hamamatsu datasheet. |