RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2414027050 - Archived data from Wed, 03. February 2021 18:16:24 CET


This is all the information about APD 2414027050. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2414027050
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E12
Break-through voltage: 414 V
Voltage for Gain 100 (T=+25°C): 385.6 V
Dark current: 8.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 19
Position in Box: 20
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jan 2019
Sent for analysis after irradiation: 25. Jan 2019
Return for assembly: none
   
Irradiation:  
Date: 21. Jan 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 22. Jan 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 386.1454535 V     T = -25 °C: 350.0449035 V
Voltage for Gain 150: T = +20 °C: 393.9539165 V     T = -25 °C: 357.5031516 V
Voltage for Gain 200: T = +20 °C: 398.2951161 V     T = -25 °C: 361.6528758 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.360400193 V-1     T = -25 °C: 4.819981215 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.001082555 V-1     T = -25 °C: 10.00733143 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.54025783 V-1     T = -25 °C: 15.47905382 V-1
Break-through voltage: T = +20 °C: 413.6275217 V     T = -25 °C: 376.9263262 V
   
Notes:


Version history

Time Author Change comment
11. Jul 2022 14:25:46 CEST oafedulidis Assigned to capsule by script
16. Jun 2021 16:03:41 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:59:58 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:52:39 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:50:14 CET jreher Updated box and position via API.
03. Feb 2021 18:16:24 CET jreher Updated box and position via API.
11. Aug 2020 17:22:49 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:32:47 CET jreher Updated APD location via API.
25. Nov 2019 17:12:22 CET jreher Updated box and position via API.
04. Jul 2019 11:08:47 CEST jreher Updated APD location via API.
12. Jun 2019 16:46:49 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:31:45 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:09:44 CEST jreher Updated APD batch assignment via API.
25. Jan 2019 14:02:11 CET markus.moritz
03. Jan 2019 00:11:43 CET Tobias Corrected dark current unit.
12. Jan 2018 13:11:47 CET Tobias Imported from Hamamatsu datasheet.