Subdetector specification:  
Serial: 2414027018
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C12
Break-through voltage: 416 V
Voltage for Gain 100 (T=+25°C): 388.1 V
Dark current: 4.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 18
Position in Box: 23
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jan 2019
Sent for analysis after irradiation: 28. Jan 2019
Return for assembly: none
   
Irradiation:  
Date: 21. Jan 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 22. Jan 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 388.7901698 V     T = -25 °C: 352.5713713 V
Voltage for Gain 150: T = +20 °C: 396.5882537 V     T = -25 °C: 360.0948298 V
Voltage for Gain 200: T = +20 °C: 400.9111576 V     T = -25 °C: 364.3065638 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.572116774 V-1     T = -25 °C: 4.857512347 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.880572901 V-1     T = -25 °C: 9.591441256 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.24883906 V-1     T = -25 °C: 14.82847573 V-1
Break-through voltage: T = +20 °C: 415.8231278 V     T = -25 °C: 379.5658655 V
   
Notes:


Version history

Time Author Change comment
26. Oct 2021 16:15:16 CEST oafedulidis Assigned to capsule by script
16. Jun 2021 16:04:11 CEST oafedulidis Updated box and position via API.
16. Jun 2021 16:00:23 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:53:03 CEST oafedulidis Updated box and position via API.
26. Apr 2021 15:21:43 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:50:08 CET jreher Updated box and position via API.
03. Feb 2021 18:16:18 CET jreher Updated box and position via API.
11. Aug 2020 17:22:43 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:32:38 CET jreher Updated APD location via API.
25. Nov 2019 17:12:19 CET jreher Updated box and position via API.
04. Jul 2019 11:08:40 CEST jreher Updated APD location via API.
12. Jun 2019 16:46:47 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:31:42 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:09:34 CEST jreher Updated APD batch assignment via API.
28. Jan 2019 11:52:43 CET markus.moritz
03. Jan 2019 00:11:41 CET Tobias Corrected dark current unit.
12. Jan 2018 13:11:47 CET Tobias Imported from Hamamatsu datasheet.