RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2414027017 - Archived data from Wed, 16. June 2021 15:53:37 CEST


This is all the information about APD 2414027017. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2414027017
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E13
Break-through voltage: 415 V
Voltage for Gain 100 (T=+25°C): 386.5 V
Dark current: 7.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 18
Position in Box: 22
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jan 2019
Sent for analysis after irradiation: 28. Jan 2019
Return for assembly: none
   
Irradiation:  
Date: 21. Jan 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 22. Jan 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 386.9501606 V     T = -25 °C: 350.7575195 V
Voltage for Gain 150: T = +20 °C: 394.8030353 V     T = -25 °C: 358.2737259 V
Voltage for Gain 200: T = +20 °C: 399.1614831 V     T = -25 °C: 362.5055673 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.47435285 V-1     T = -25 °C: 4.763177969 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.591317502 V-1     T = -25 °C: 9.383478147 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.45691227 V-1     T = -25 °C: 14.35431109 V-1
Break-through voltage: T = +20 °C: 414.7928793 V     T = -25 °C: 378.1547695 V
   
Notes:


Version history

Time Author Change comment
19. Nov 2021 13:05:28 CET oafedulidis Assigned to capsule by script
16. Jun 2021 16:04:42 CEST oafedulidis Updated box and position via API.
16. Jun 2021 16:00:52 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:53:37 CEST oafedulidis Updated box and position via API.
26. Apr 2021 15:21:43 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:50:08 CET jreher Updated box and position via API.
03. Feb 2021 18:16:18 CET jreher Updated box and position via API.
11. Aug 2020 17:22:43 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:32:38 CET jreher Updated APD location via API.
25. Nov 2019 17:12:19 CET jreher Updated box and position via API.
04. Jul 2019 11:08:40 CEST jreher Updated APD location via API.
12. Jun 2019 16:46:47 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:31:42 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:09:34 CEST jreher Updated APD batch assignment via API.
28. Jan 2019 12:11:02 CET markus.moritz
28. Jan 2019 12:10:21 CET markus.moritz
03. Jan 2019 00:11:41 CET Tobias Corrected dark current unit.
12. Jan 2018 13:11:47 CET Tobias Imported from Hamamatsu datasheet.