RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2413026946 - Archived data from Tue, 06. October 2020 16:52:12 CEST


This is all the information about APD 2413026946. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2413026946
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C06
Break-through voltage: 412 V
Voltage for Gain 100 (T=+25°C): 382.9 V
Dark current: 8.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 28
Position in Box: 32
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 12. Nov 2018
Sent for analysis after irradiation: 26. Nov 2018
Return for assembly: none
   
Irradiation:  
Date: 22. Nov 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 23. Nov 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 383.1322045 V     T = -25 °C: 347.5455932 V
Voltage for Gain 150: T = +20 °C: 391.0047863 V     T = -25 °C: 354.9843793 V
Voltage for Gain 200: T = +20 °C: 395.3885173 V     T = -25 °C: 359.1533144 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.449545652 V-1     T = -25 °C: 4.953497081 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.536838531 V-1     T = -25 °C: 8.99049377 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.35416755 V-1     T = -25 °C: 15.51253328 V-1
Break-through voltage: T = +20 °C: 410.9886409 V     T = -25 °C: 374.3969979 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:51:28 CET jreher Updated box and position via API.
03. Feb 2021 18:17:34 CET jreher Updated box and position via API.
29. Jan 2021 10:24:39 CET jreher Assigned to capsule by script
06. Oct 2020 16:52:12 CEST jreher Updated box and position via API.
11. Aug 2020 17:24:17 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:34:28 CET jreher Updated APD location via API.
25. Nov 2019 17:13:05 CET jreher Updated box and position via API.
04. Jul 2019 11:10:02 CEST jreher Updated APD location via API.
12. Jun 2019 16:47:31 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:32:26 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:11:39 CET Tobias Corrected dark current unit.
26. Nov 2018 13:12:31 CET markus.moritz
16. Nov 2018 15:03:59 CET markus.moritz
12. Jan 2018 13:11:46 CET Tobias Imported from Hamamatsu datasheet.