Subdetector specification:  
Serial: 2412026870
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E12
Break-through voltage: 415 V
Voltage for Gain 100 (T=+25°C): 386.6 V
Dark current: 7.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 17
Position in Box: 18
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 12. Nov 2018
Sent for analysis after irradiation: 26. Nov 2018
Return for assembly: none
   
Irradiation:  
Date: 22. Nov 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 23. Nov 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 386.9434685 V     T = -25 °C: 350.9550228 V
Voltage for Gain 150: T = +20 °C: 394.7512502 V     T = -25 °C: 358.4243348 V
Voltage for Gain 200: T = +20 °C: 399.0978634 V     T = -25 °C: 362.5993713 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.580810057 V-1     T = -25 °C: 4.810276159 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.963543398 V-1     T = -25 °C: 9.651392775 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.52454446 V-1     T = -25 °C: 15.05495566 V-1
Break-through voltage: T = +20 °C: 414.2415128 V     T = -25 °C: 377.6044065 V
   
Notes: foam


Version history

Time Author Change comment
19. Nov 2021 13:05:29 CET oafedulidis Assigned to capsule by script
16. Jun 2021 16:04:39 CEST oafedulidis Updated box and position via API.
16. Jun 2021 16:00:50 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:53:34 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:49:57 CET jreher Updated box and position via API.
03. Feb 2021 18:16:07 CET jreher Updated box and position via API.
11. Aug 2020 17:22:29 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:32:25 CET jreher Updated APD location via API.
25. Nov 2019 17:12:13 CET jreher Updated box and position via API.
04. Jul 2019 11:08:30 CEST jreher Updated APD location via API.
12. Jun 2019 16:46:40 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:31:36 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:09:15 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:11:37 CET Tobias Corrected dark current unit.
26. Nov 2018 13:05:54 CET markus.moritz
16. Nov 2018 12:15:21 CET markus.moritz
12. Jan 2018 13:11:45 CET Tobias Imported from Hamamatsu datasheet.