This is all the information about APD 2412026839. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2412026839
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D04
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 380.8 V
Dark current: 8.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 17
Position in Box: 6
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 12. Nov 2018
Sent for analysis after irradiation: 26. Nov 2018
Return for assembly: none
   
Irradiation:  
Date: 22. Nov 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 23. Nov 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.0434746 V     T = -25 °C: 345.6578401 V
Voltage for Gain 150: T = +20 °C: 388.9410214 V     T = -25 °C: 353.1145585 V
Voltage for Gain 200: T = +20 °C: 393.3628958 V     T = -25 °C: 357.3117943 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.428019748 V-1     T = -25 °C: 4.841833347 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.119951 V-1     T = -25 °C: 9.483069704 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.73509889 V-1     T = -25 °C: 14.50185182 V-1
Break-through voltage: T = +20 °C: 408.5980337 V     T = -25 °C: 372.4063992 V
   
Notes: foam


Version history

Time Author Change comment
15. Nov 2022 13:36:57 CET oafedulidis Assigned to capsule by script
05. Feb 2021 10:49:55 CET jreher Updated box and position via API.
03. Feb 2021 18:16:06 CET jreher Updated box and position via API.
11. Aug 2020 17:22:27 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:32:24 CET jreher Updated APD location via API.
25. Nov 2019 17:12:12 CET jreher Updated box and position via API.
04. Jul 2019 11:08:29 CEST jreher Updated APD location via API.
12. Jun 2019 16:46:39 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:31:34 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:09:08 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:11:37 CET Tobias Corrected dark current unit.
26. Nov 2018 12:30:59 CET markus.moritz
16. Nov 2018 12:19:16 CET markus.moritz
12. Jan 2018 13:11:44 CET Tobias Imported from Hamamatsu datasheet.