Subdetector specification:  
Serial: 2411026790
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D14
Break-through voltage: 411 V
Voltage for Gain 100 (T=+25°C): 382.4 V
Dark current: 5.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 16
Position in Box: 26
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 12. Nov 2018
Sent for analysis after irradiation: 13. Dec 2018
Return for assembly: none
   
Irradiation:  
Date: 07. Dec 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 10. Dec 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 382.5904564 V     T = -25 °C: 347.0701075 V
Voltage for Gain 150: T = +20 °C: 390.4630326 V     T = -25 °C: 354.521506 V
Voltage for Gain 200: T = +20 °C: 394.8624658 V     T = -25 °C: 358.741108 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.390379445 V-1     T = -25 °C: 4.851264909 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.907793059 V-1     T = -25 °C: 9.097005346 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.56379358 V-1     T = -25 °C: 15.70887536 V-1
Break-through voltage: T = +20 °C: 410.3259771 V     T = -25 °C: 373.9811211 V
   
Notes:


Version history

Time Author Change comment
17. Jun 2021 18:52:19 CEST oafedulidis Assigned to capsule by script
16. Feb 2021 12:26:52 CET jreher Updated box and position via API.
05. Feb 2021 10:49:50 CET jreher Updated box and position via API.
03. Feb 2021 18:16:00 CET jreher Updated box and position via API.
11. Aug 2020 17:22:22 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:32:15 CET jreher Updated APD location via API.
25. Nov 2019 17:12:09 CET jreher Updated box and position via API.
04. Jul 2019 11:08:23 CEST jreher Updated APD location via API.
12. Jun 2019 16:46:36 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:31:31 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:09:01 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:11:36 CET Tobias Corrected dark current unit.
13. Dec 2018 13:20:05 CET markus.moritz
23. Nov 2018 11:47:19 CET markus.moritz
12. Jan 2018 13:11:44 CET Tobias Imported from Hamamatsu datasheet.