RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2411026784 - Archived data from Wed, 03. February 2021 18:15:59 CET


This is all the information about APD 2411026784. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2411026784
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E03
Break-through voltage: 417 V
Voltage for Gain 100 (T=+25°C): 389.1 V
Dark current: 4.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 16
Position in Box: 20
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 12. Nov 2018
Sent for analysis after irradiation: 13. Dec 2018
Return for assembly: none
   
Irradiation:  
Date: 07. Dec 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 10. Dec 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 389.5835056 V     T = -25 °C: 353.4406272 V
Voltage for Gain 150: T = +20 °C: 397.4803237 V     T = -25 °C: 361.0255877 V
Voltage for Gain 200: T = +20 °C: 401.8036632 V     T = -25 °C: 365.2595842 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.491400505 V-1     T = -25 °C: 4.662175123 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.696751361 V-1     T = -25 °C: 9.064913648 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.66922658 V-1     T = -25 °C: 16.10149822 V-1
Break-through voltage: T = +20 °C: 416.7954326 V     T = -25 °C: 380.3204558 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:49:49 CET jreher Updated box and position via API.
03. Feb 2021 18:15:59 CET jreher Updated box and position via API.
11. Aug 2020 17:22:21 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:32:14 CET jreher Updated APD location via API.
25. Nov 2019 17:12:08 CET jreher Updated box and position via API.
04. Jul 2019 11:08:22 CEST jreher Updated APD location via API.
12. Jun 2019 16:46:36 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:31:31 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:09:01 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:11:35 CET Tobias Corrected dark current unit.
13. Dec 2018 13:17:43 CET markus.moritz
23. Nov 2018 11:49:12 CET markus.moritz
12. Jan 2018 13:11:44 CET Tobias Imported from Hamamatsu datasheet.