Show Hamamatsu Avalanche Photo Diode 2411026783 - Archived data from Wed, 03. February 2021 18:15:59 CET
This is all the information about APD 2411026783. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2411026783 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | assigned to 2317025590/2411026783 |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | red |
Manufacturer information: | |
Wafer position: | E05 |
Break-through voltage: | 413 V |
Voltage for Gain 100 (T=+25°C): | 385.1 V |
Dark current: | 4 nA |
Screening Logistics: | |
Available: | No |
Storage Box: | 16 |
Position in Box: | 19 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | 12. Nov 2018 |
Sent for analysis after irradiation: | 13. Dec 2018 |
Return for assembly: | none |
Irradiation: | |
Date: | 07. Dec 2018 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 10. Dec 2018 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 385.5428435 V T = -25 °C: 349.658475 V |
Voltage for Gain 150: | T = +20 °C: 393.3660428 V T = -25 °C: 357.1406803 V |
Voltage for Gain 200: | T = +20 °C: 397.7185719 V T = -25 °C: 361.3362875 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.421822669 V-1 T = -25 °C: 4.920242598 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.473803291 V-1 T = -25 °C: 9.032696675 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 15.29387511 V-1 T = -25 °C: 16.60328406 V-1 |
Break-through voltage: | T = +20 °C: 412.480913 V T = -25 °C: 376.1008404 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:49:49 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:15:59 CET | jreher | Updated box and position via API. |
08. Dec 2020 17:17:54 CET | jreher | Assigned to capsule by script |
06. Oct 2020 16:53:07 CEST | jreher | Updated box and position via API. |
11. Aug 2020 17:22:21 CEST | jreher | Updated APD characteristics via API. |
27. Nov 2019 19:32:14 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:12:08 CET | jreher | Updated box and position via API. |
04. Jul 2019 11:08:22 CEST | jreher | Updated APD location via API. |
12. Jun 2019 16:46:36 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 16:31:31 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 15:09:01 CEST | jreher | Updated APD batch assignment via API. |
03. Jan 2019 00:11:35 CET | Tobias | Corrected dark current unit. |
13. Dec 2018 13:17:05 CET | markus.moritz | |
23. Nov 2018 11:49:28 CET | markus.moritz | |
12. Jan 2018 13:11:43 CET | Tobias | Imported from Hamamatsu datasheet. |