RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2411026783 - Archived data from Wed, 03. February 2021 18:15:59 CET


This is all the information about APD 2411026783. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2411026783
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2317025590/2411026783
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: red
   
Manufacturer information:  
Wafer position: E05
Break-through voltage: 413 V
Voltage for Gain 100 (T=+25°C): 385.1 V
Dark current: 4 nA
   
Screening Logistics:  
Available: No
Storage Box: 16
Position in Box: 19
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 12. Nov 2018
Sent for analysis after irradiation: 13. Dec 2018
Return for assembly: none
   
Irradiation:  
Date: 07. Dec 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 10. Dec 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 385.5428435 V     T = -25 °C: 349.658475 V
Voltage for Gain 150: T = +20 °C: 393.3660428 V     T = -25 °C: 357.1406803 V
Voltage for Gain 200: T = +20 °C: 397.7185719 V     T = -25 °C: 361.3362875 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.421822669 V-1     T = -25 °C: 4.920242598 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.473803291 V-1     T = -25 °C: 9.032696675 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.29387511 V-1     T = -25 °C: 16.60328406 V-1
Break-through voltage: T = +20 °C: 412.480913 V     T = -25 °C: 376.1008404 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:49:49 CET jreher Updated box and position via API.
03. Feb 2021 18:15:59 CET jreher Updated box and position via API.
08. Dec 2020 17:17:54 CET jreher Assigned to capsule by script
06. Oct 2020 16:53:07 CEST jreher Updated box and position via API.
11. Aug 2020 17:22:21 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:32:14 CET jreher Updated APD location via API.
25. Nov 2019 17:12:08 CET jreher Updated box and position via API.
04. Jul 2019 11:08:22 CEST jreher Updated APD location via API.
12. Jun 2019 16:46:36 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:31:31 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:09:01 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:11:35 CET Tobias Corrected dark current unit.
13. Dec 2018 13:17:05 CET markus.moritz
23. Nov 2018 11:49:28 CET markus.moritz
12. Jan 2018 13:11:43 CET Tobias Imported from Hamamatsu datasheet.